Detailed Flow
- INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
: GO TO 2.
- SYMPTOM CHECK
Check the symptom from the customer's information. Check that any symptom occurs other than the interviewed symptom.
Insufficient cooling/heating: GO TO 3.
Refrigerant leakage: GO TO 6.
Noise: GO TO 7.
- CONTROL SYSTEM DIAGNOSIS
Perform the system diagnosis for the A/C control system. Refer to "DIAGNOSIS AND REPAIR WORK FLOW ".
Is A/C control system normal?
YES: GO TO 4.
NO: GO TO 8.
- PERFORMANCE TEST
Perform the performance test. Check the operation of each part. Refer to "INSPECTION ".
: GO TO 5.
- TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE
Diagnose using a manifold gauge whenever system's high and/or low side pressure(s) is/are unusual. Specify the malfunctioning part. Refer to "SYMPTOM TABLE ".
Low refrigerant charge: GO TO 6.
Except above: GO TO 8.
- CHECK REFRIGERANT FOR LEAKAGES
Check refrigerant for leakages. Specify the malfunctioning part. Refer to "LEAK TEST ".
: GO TO 8.
- TROUBLE DIAGNOSIS FOR NOISE
Perform trouble diagnosis for noise. Specify the malfunctioning part. Refer to "SYMPTOM TABLE ".
: GO TO 8.
- MALFUNCTION PART REPAIR
Repair or replace the malfunctioning part.
: GO TO 9.
- REPAIR CHECK (OPERATION CHECK)
Check the operation of each part.
Does it operate normally?
YES: INSPECTION END
NO: GO TO 2.