TROUBLE DIAGNOSIS CHART OF RGB IMAGE

Symptoms Check items Possible malfunction location/Action to take
RGB image is not shown. There is malfunction in the CONSULT-III self-diagnosis result.
Refer to "CONSULT - III FUNCTION ".
Perform detected DTC diagnosis. Refer to "DTC INDEX ".
There is no malfunction in CONSULT-III self-diagnosis results.
Refer to "CONSULT - III FUNCTION ".
Vertical synchronizing (VP) signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
Color of RGB image is not proper. Light blue (Cyan) tint. RGB signal (R: red) circuit.
Refer to "DIAGNOSIS PROCEDURE ".
Purple (Magenta) tint. RGB signal (G: green) circuit.
Refer to "DIAGNOSIS PROCEDURE ".
Screen looks yellowish. RGB signal (B: blue) circuit.
Refer to "DIAGNOSIS PROCEDURE ".
RGB screen is rolling. - RGB synchronizing signal circuit.
Refer to "DIAGNOSIS PROCEDURE ".