Aiming Adjustment: Notes
WARNING: This page is about a different car, the 2008 Infiniti FX45 and 2008 Infiniti FX35. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:
Complete all necessary work for laser beam adjustment until the adjustment completes as shown in the procedure. If the procedure does not complete, the ICC system is inoperable.
NOTE:
CONSULT-III basic operation: Refer to
"CONSULT-III/GST CHECKING SYSTEM
".
- Touch "WORK SUPPORT".
- Touch "LASER BEAM ADJUST".
- Touch "START".CAUTION: If the adjustment screen does not appear on the CONSULT-III screen in 10 seconds. After touching "LASER BEAM ADJUST" screen, the following causes may be considered:
- Target is not set accurately.
- There is not enough space beside the target.
- Deformation of vehicle or the surrounding equipment unit, bracket, or the surrounding equipment is causing inappropriate installation of sensor and aiming may be set out of the adjustable range.
- The area is not suitable for the adjustment work.
- ICC sensor is not clean.
- After the CONSULT-III displays "ADJUST THE VERTICAL OF LASER BEAM AIMING" turn the up-down direction adjusting screw until "U/D CORRECT" value is set in the range of ± 4.CAUTION: Turn the screw slowly. The value change on display is slower than actual movement of the ICC sensor. Wait for 2 seconds every time the screw is turned half a rotation.NOTE: Turning the screw to the right lowers the aiming and to the left lifts the aiming.
- When "U/D CORRECT" value indicates ±4, confirm that the margin of value remains within ±4 at least for 2 seconds with no equipment or hand touching the ICC sensor. When "COMPLETED THE VERTICAL AIMING OF LASER BEAM" appears on screen, touch "END".CAUTION: Be sure that the margin of "U/D CORRECT" is within ±4 with ICC sensor unit is untouched.
- Confirm that "ADJUSTING AUTOMATIC HORIZONTAL LASER BEAM AIMING" is on screen and wait for a while (maximum: 10 seconds).
- Confirm that "NORMALLY COMPLETED" is displayed on CONSULT-III and close the aiming adjustment procedure by touching "END".
CAUTION:
Complete all the procedures once "LASER BEAM ADJUST" mode is entered in CONSULT-III. When the procedure is discontinued, the ICC system is inoperable.