Inspection Procedure
HINT:
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
- Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.NOTE: After the ignition switch is turned OFF, the navigation system requires approximately 90 seconds to record various types of memory and settings. As a result, after turning the ignition switch OFF, wait 90 seconds or more before disconnecting the cable from the negative (-) battery terminal.
- Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
- CHECK DLC3
- Measure the resistance according to the value(s) in the table below.
Result
RESULT REFERENCE TABLETester Connection Switch Condition Measured Resistance Proceed to J17-6 (CANH) - J17-14 (CANL) Ignition switch OFF 54 to 69 Ω OK 69 Ω or higher NG NOTE: When the measured value is 132 Ω or higher and a CAN communication system DTC is output, there may be a problem besides disconnection of the DLC3 branch wire. For that reason, troubleshooting should be performed again from HOW TO PROCEED WITH TROUBLESHOOTING after repairing the trouble area.
NG: REPAIR OR REPLACE CAN BRANCH WIRE CONNECTED TO DLC3 (CANH, CANL)
OK: Go to Next Step
- Measure the resistance according to the value(s) in the table below.
- CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - ECM)
- Disconnect the J94 No. 1 junction connector connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATION TABLETester Connection Switch Condition Specified Condition J94-1 (CANH) - J94-2 (CANL) Ignition switch OFF 108 to 132 Ω
NG: Go to step 5
OK: Go to Next Step
- CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - COMBINATION METER ECU)
- Disconnect the J84 No. 1 junction connector connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATION TABLETester Connection Switch Condition Specified Condition J84-1 (CANH) - J84-2 (CANL) Ignition switch OFF 108 to 132 Ω
NG: Go to step 10
OK: REPLACE NO. 1 JUNCTION CONNECTOR
- CONNECT CONNECTOR
- Reconnect the J94 No. 1 junction connector connector.
- CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - ECM)
- Disconnect the J92 No. 2 junction connector connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATION TABLETester Connection Switch Condition Specified Condition J92-1 (CANH) - J92-2 (CANL) Ignition switch OFF 108 to 132 Ω
NG: Go to step 8
OK: Go to Next Step
- CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR)
- Disconnect the J93 No. 2 junction connector connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATION TABLETester Connection Switch Condition Specified Condition J93-1 (CANH) - J93-2 (CANL) Ignition switch OFF 108 to 132 Ω
NG: REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (NO. 1 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR)
OK: REPLACE NO. 2 JUNCTION CONNECTOR
- CONNECT CONNECTOR
- Reconnect the J92 No. 1 junction connector connector.
- CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM - NO. 2 JUNCTION CONNECTOR)
- Disconnect the A24 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATION TABLETester Connection Switch Condition Specified Condition A24-10 (CANH) - A24-11 (CANL) Ignition switch OFF 108 to 132 Ω Result
RESULT REFERENCE TABLEResult Proceed to OK (for 1GR-FE) A OK (for 2UZ-FE) B OK (for 3UR-FE) C NG D
B: REPLACE ECM (See REMOVAL )
C: REPLACE ECM (See REMOVAL )
D: REPAIR OR REPLACE CAN MAIN WIRE CONNECTED TO ECM (ECM - NO. 2 JUNCTION CONNECTOR)
A: REPLACE ECM (See REMOVAL )
- CONNECT CONNECTOR
- Reconnect the J84 No. 1 junction connector connector.
- CHECK FOR OPEN IN CAN BUS MAIN WIRE (COMBINATION METER ECU - NO. 1 JUNCTION CONNECTOR)
- Disconnect the J28 combination meter ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATION TABLETester Connection Switch Condition Specified Condition J28-33 (CANH) - J28-34 (CANL) Ignition switch OFF 108 to 132 Ω
NG: REPAIR OR REPLACE CAN MAIN WIRE CONNECTED TO COMBINATION METER ECU (COMBINATION METER ECU - NO. 1 JUNCTION CONNECTOR)
OK: REPLACE COMBINATION METER ASSEMBLY (See REMOVAL )