Automatic Door Lock/Unlock Function (Unlock Operation)
The automatic door lock/unlock function is the function that unlocks all doors linked with the key position or shift position. It has 2 types as follows.
IGN OFF Interlock Door Unlock*1
All doors are unlocked when the power supply position is changed from ON to OFF.
BCM outputs the unlock signal to all door lock actuators when it detects that the power supply position is changed from ignition switch ON to OFF.
P Range Interlock Door Unlock
All doors are unlocked when shifting the selector lever from any position other than the P to P position.
BCM outputs the unlock signal to all door lock actuators when it detects that the ignition switch is in the ON position and the shift signal received from TCM via CAN communication is shifted from any position other than the P to P position.
Setting change of Automatic Door Lock/Unlock Function
The unlock operation setting of the automatic door lock/unlock function can be changed.
With CONSULT-III
The ON/OFF switching of the automatic door lock/unlock function and the type selection of the automatic door lock/unlock function can be performed at the WORK SUPPORT setting of CONSULT-III.
Without CONSULT-III
The automatic door lock/unlock function ON/OFF can be switched by performing the following operation.
- Close all doors below (door switch OFF)
- Turn ignition switch ON
- Press and hold the door lock and unlock switch for 5 seconds or more in the unlock direction within 20 seconds after turning the power supply position ON.
- The switching is completed when the hazard lamp blinks.
OFF → ON: 2 blinks
ON → OFF: 1 blink
*1: This function is set to ON before delivery.