A/T Indicator Is Malfunction
- CHECK SEGMENTS OF A/T INDICATOR
Perform self-diagnosis mode of combination meter. Refer to "OPERATION PROCEDURE ".
Are all segments displayed?
YES: GO TO 2.
No: Replace combination meter.
- CHECK UNIFIED METER AND A/C AMP. (CONSULT-III)
Perform self-diagnosis of unified meter and A/C amp. Refer to "CONSULT-III Function (METER A/C AMP) ".
Self-diagnostic results content
No malfunction detected: GO TO 3.
Malfunction detected >> Check applicable parts, and repair or replace corresponding parts.
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
Use "Data Monitor" of "METER/M&A" on CONSULT-III. Confirm each indication on the monitor when operating the shift lever.
SWITCH OPERATION AND OPERATION STATUSDisplay item Switch operation Operation status AT-M IND Manual mode range ON Except for manual mode range OFF AT-M GEAR Manual mode range (shift- up or down) 5 - 1 Except for manual mode range 1 P RANGE IND P range ON Except for P range OFF R RANGE IND R range ON Except for R range OFF N RANGE IND N range ON Except for N range OFF D RANGE IND D range ON Except for D range OFF OK or NG
OK: Replace combination meter.
NG: GO TO 4.
- CHECK TCM (CONSULT-III)
Perform self-diagnosis of TCM. Refer to "CONSULT-III FUNCTION (A/T) ".
Self-diagnostic results content
No malfunction detected >> Check TCM input/output signal. Refer to "TCM INPUT/OUTPUT SIGNAL REFERENCE VALUES ".
Malfunction detected >> Check applicable part, and repair or replace corresponding parts.