Component Inspection
- CHECK SELECTOR LEVER POSITION INDICATOR
Check that selector lever position indicator lamps turn on.
CAUTION: Connect the fuse between the terminals when applying the voltage.TERMINALS CONDITION AND STATUS REFERENCE(+) (fuse) (-) Condition Status Selector lever position indicator connector Connector Terminal Connector Terminal M221 2 M221 7 Apply 12 V direct current between terminals 2 and 7. "N" position indicator lamp turns on. 3 Apply 12 V direct current between terminals 3 and 7. "D" position indicator lamp turns on. 4 Apply 12 V direct current between terminals 4 and 7. "R" position indicator lamp turns on. 5 Apply 12 V direct current between terminals 5 and 7. "P" position indicator lamp turns on. 6 9 Apply 12 V direct current between terminals 6 and 9. "M" mode indicator lamp turns on. 10 11 Apply 12 V direct current between terminals 10 and 11. Illumination lamp turns on. Is the inspection result normal?
YES: INSPECTION END
NO: Replace the malfunctioning part. Refer to "EXPLODED VIEW ".