Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK BATTERY CURRENT SENSOR POWER SUPPLY CIRCUIT-I
- Disconnect battery current sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between battery current sensor harness connector and ground.TERMINALS VOLTAGE REFERENCE
Battery current sensor Ground Voltage Connector Terminal E21 1 Ground Approx. 5V
Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 3.
- CHECK BATTERY CURRENT SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between battery current sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
Battery current sensor ECM Continuity Connector Terminal Connector Terminal E21 1 F102 64 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F1, E3
- Harness for open or short between battery current sensor and ECM
Repair open circuit or short to ground or short to power in harness connectors.
- CHECK BATTERY CURRENT SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between battery current sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
Battery current sensor ECM Continuity Connector Terminal Connector Terminal E21 2 F102 95 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 6.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F1, E3
- Harness for open or short between battery current sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK BATTERY CURRENT SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between battery current sensor harness connector and ECM harness connector.TERMINALS CONTINUITY REFERENCE
Battery current sensor ECM Continuity Connector Terminal Connector Terminal E21 3 F102 91 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 9.
NO: GO TO 8.
- Check the continuity between battery current sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F1, E3
- Harness for open or short between battery current sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK BATTERY CURRENT SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 10.
NO: Replace battery negative cable assembly.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END