LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2008 >> G37 Base >> Repair and Diagnosis >> Brakes >> Traction Control >> Brake Control System >> Function Diagnosis >> Diagnosis System [Abs Actuator And Electric Unit (Control Unit)] >> CONSULT-III Function >> Active Test Mode >> Abs Solenoid Valve

Abs Solenoid Valve

ABS SOLENOID VALVE ACTIVE TEST REFERENCE

Test item Display item ((2)) Display
Up Keep Down
FR RH SOL FR RH IN SOL Off On On
FR RH OUT SOL Off Off On(1)
USV [FR-RL] Off Off Off Off
HSV [FR-RL] Off Off Off
FR LH SOL FR LH IN SOL Off On On
FR LH OUT SOL Off Off On(1)
USV [FL-RR] Off Off Off
HSV [FL-RR] Off Off Off
RR RH SOL RR RH IN SOL Off On On
RR RH OUT SOL Off Off On(1)
USV [FL-RR] Off Off Off
HSV [FL-RR] Off Off Off
RR LH SOL RR LH IN SOL Off On On
RR LH OUT SOL Off Off On(1)
USV [FR-RL] Off Off Off
HSV [FR-RL] Off Off Off
(1) On for 1 to 2 seconds after the touch, and then Off.
(2) A brief moment of On/Off condition occurs every 20 seconds after ignition switch turned ON. This is not malfunction because it is an operation for checking.