LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2008 >> G35 x >> Repair and Diagnosis >> External Pages >> Different car >> Section 48 (Automatic Drive Positioner) >> Ecu Diagnosis >> Automatic Drive Positioner Control Unit >> Reference Value >> Physical Values

Physical Values

WARNING: This page is about a different car, the 2008 Infiniti QX56. However, it is still accessible from the selected car via links, so may be relevant.
PHYSICAL VALUES

Terminal Wire Color Item Condition Voltage (V) (Approx.)
1 W/G ADP steering switch TILT UP ADP steering switch in UP position 0
Other than above 5
2 LG Changeover switch RH signal Changeover switch in RH position 0
Other than above 5
3 Y/B Mirror switch UP signal Mirror switch in UP position 0
Other than above 5
4 V/W Mirror switch LEFT signal Mirror switch in LEFT position 0
Other than above 5
5 R/B Mirror sensor (RH vertical) signal Mirror motor RH is operated UP or DOWN Changes between 3.4 (close to peak) 0.6 (close to valley)
6 L/Y Mirror sensor (LH vertical) signal Mirror motor LH is operated UP or DOWN Changes between 3.4 (close to peak) 0.6 (close to valley)
7 Y/BR Tilt sensor input Tilt position TOP 2
Tilt position BOTTOM 4
8 BR/Y Pedal sensor input signal Pedal position front end 0.5
Pedal position rear end 4.5
9 LG/B Seat memory switch 1 signal Memory switch 1 ON 0
Memory switch 1 OFF 5
10 L UART LINE (TX) Pedal adjusting switch ON (FORWARD or BACKWARD operation)
G04902962Courtesy of NISSAN MOTOR CO., U.S.A.
12 P Seat memory switch indictor 1 signal Memory switch 1 ON 0
Memory switch 1 OFF Battery voltage
13 Y/G Seat memory switch indictor 2 signal Memory switch 2 ON 0
Memory switch 2 OFF Battery voltage
14 GR/R Mirror motor RH UP signal Mirror motor RH is operated UP 1.5 - Battery voltage
Other than above 0
15 V/R Mirror motor RH LEFT signal Mirror motor RH is operated LEFT 1.5 - Battery voltage
Other than above 0
16 O Mirror motor LH DOWN signal Mirror motor LH is operated DOWN 1.5 - Battery voltage
Other than above 0
Mirror motor LH RIGHT signal Mirror motor LH is operated RIGHT 1.5 - Battery voltage
Other than above 0
17 G/B ADP steering switch TILT DOWN ADP steering switch in DOWN position 0
Other than above 5
18 BR/W Changeover switch LH signal Changeover switch in LH position 0
Other than above 5
19 SB Mirror switch DOWN signal Mirror switch in DOWN position 0
Other than above 5
20 GR Mirror switch RIGHT signal Mirror switch in RIGHT position 0
Other than above 5
21 L/W Mirror sensor (RH horizontal) signal Mirror motor RH is operated LEFT or RIGHT Changes between 3.4 (close to left edge) 0.6 (close to right edge)
22 G Mirror sensor (LH horizontal) signal Mirror motor LH is operated LEFT or RIGHT Changes between 3.4 (close to left edge) 0.6 (close to right edge)
24 G/O Seat memory set switch signal Set switch 1 ON 0
Set switch 1 OFF 5
25 P/L Seat memory switch 2 signal Memory switch 2 ON 0
Memory switch 2 OFF 5
26 W UART LINE (RX) Pedal adjusting switch ON (FORWARD or BACKWARD operation)
G04902965Courtesy of NISSAN MOTOR CO., U.S.A.
30 Y Mirror motor RH DOWN signal Mirror motor RH is operated DOWN 1.5 - Battery voltage
Other than above 0
Mirror motor RH RIGHT signal Mirror motor RH is operated RIGHT 1.5 - Battery voltage
Other than above 0
31 R Mirror motor LH UP signal Mirror motor LH is operated UP 1.5 - Battery voltage
Other than above 0
32 BR Mirror motor LH LEFT signal Mirror motor LH is operated LEFT 1.5 - Battery voltage
Other than above 0
33 W/L Sensor power supply - 5
34 Y/R Battery power supply - Battery voltage
35 R Tilt motor UP signal ADP steering switch in UP position Battery voltage
Other than above 0
37 G Pedal adjust motor FORWARD signal Pedal adjust motor FORWARD operation (Motor operated) Battery voltage
Other than above 0
39 L/B Battery power supply - Battery voltage
40 B/W Ground - 0
41 W/G Sensor ground - 0
42 V Tilt motor DOWN signal ADP steering switch in DOWN position Battery voltage
Other than above 0
45 R Pedal adjust motor BACKWARD signal Pedal adjust motor BACKWARD operation (Motor operated) Battery voltage
Other than above 0
48 B Ground - 0