Diagnosis Procedure
- INSPECTION START
Check the case in which DTC is detected.
- Case1: It is detected when push-button ignition switch is pressed for 1 second
- Case2: It is detected after Intelligent Key is inserted into key slot and push-button ignition switch is pressed
In which case is DTC detected?
Case1 >> GO TO 2.
Case2 >> GO TO 4.
- CHECK PUSH-BUTTON IGNITION SWITCH OUTPUT SIGNAL 1
- Turn ignition switch OFF.
- Disconnect push-button ignition switch harness connector and IPDM E/R harness connector E5.
- Check voltage between push-button ignition switch harness connector and ground.TERMINALS VOLTAGE REFERENCE
Push-button ignition switch Ground Voltage (V) Connector Terminal M50 4 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 3.
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT
- Disconnect BCM harness connector.
- Check continuity between push-button ignition switch harness connector and BCM harness connector.TERMINALS CONTINUITY REFERENCE
Push-button ignition switch BCM Continuity Connector Terminal Connector Terminal M50 4 M122 89 Existed - Check continuity between push-button ignition switch harness connector and ground.TERMINALS CONTINUITY REFERENCE
Push-button ignition switch Ground Continuity Connector Terminal M50 4 Ground Not existed
Is the inspection result normal?
YES: GO TO 6.
NO: Repair harness or connector.
- CHECK PUSH-BUTTON IGNITION SWITCH OUTPUT SIGNAL 2
- Turn ignition switch OFF.
- Disconnect push-button ignition switch harness connector and BCM harness connector.
- Check voltage between push-button ignition switch harness connector and ground.TERMINALS VOLTAGE REFERENCE
Push-button ignition switch Ground Voltage (V) Connector Terminal M50 4 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- CHECK PUSH-BUTTON IGNITION SWITCH
- Disconnect IPDM E/R harness connector.
- Check continuity between push-button ignition switch harness connector and IPDM E/R harness connector.TERMINALS CONTINUITY REFERENCE
Push-button ignition switch IPDM E/R Continuity Connector Terminal Connector Terminal M50 4 E5 28 Existed - Check continuity between push-button ignition switch harness connector and ground.TERMINALS CONTINUITY REFERENCE
Push-button ignition switch Ground Continuity Connector Terminal M50 4 Ground Not existed
Is the inspection result normal?
YES: GO TO 6.
NO: Repair harness or connector.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END