Engine Control System - Component Testing And Specifications (VK45DE)
>>
Variable Induction Air Control System (VIAS)
>>
CONSULT-II Reference Value in Data Monitor Mode
CONSULT-II Reference Value in Data Monitor Mode
CONSULT-II REFERENCE VALUE IN DATA MONITOR MODE
MONITOR ITEM
CONDITION
SPECIFICATION
VIAS S/V
Selector lever: P or N
ON
Engine speed: More than 5, 000 rpm
Selector lever: Except P or N
Engine speed: Less than 5, 000 rpm
OFF