LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2006 >> Q45 >> Repair and Diagnosis >> Body & Frame >> Seats >> Climate Controlled Seat >> System Description

System Description

The climate controlled seat system is controlled by climate controlled seat control unit.

Heating and cooling are possible for a Thelma electric device (heat conversion machine).

NOTE:
  • The climate controlled seat system is downed when the temperature sensor set as the seat cushion and the seat back's thermal electric device machine detects 20 °C (68 °F)or more of mutual differences of temperature.
  • In this case, by turning off ignition switch, system down is canceled and it can be reused by turning on ignition switch again.
  • The climate controlled seat blower keep low speed for approximately 60 seconds after turning the temperature switch or the dial.
CAUTION:
  • The thermal electric device has the character in which, as for an opposite side. one side becomes high temperature at the time of low temperature.
  • At the time of work, please turn OFF a switch, and carry it out after checking that the thermal electric device has got cold.

Power is at all times supplied

When the ignition switch turned to ON or START position,

Power is supplied

Then ground is supplied

Then climate controlled seat relay is energized,

When climate controlled seat relay is turned to ON,

Power is supplied,

When climate controlled seat relay is turned to ON,

Power is supplied,

When climate controlled switch select "HEAT", ground is supply

Then, the climate controlled control unit receives climate controlled switch "HEAT" signal.

When climate controlled switch select "COOL", ground is supply

Then, the climate controlled control unit receives climate controlled switch "COOL" signal.

When the climate controlled seat control unit receives climate controlled seat switch signal, power is supply

And then ground is supplied

Then, the climate controlled seat control unit receives climate controlled seat temperature dial signal.

When blower motor rotates, signal is transmitted

This is climate controlled seat blower motor tachometer signal.

When climate controlled seat control unit receives climate controlled seat switch (HEAT, COOL) signal, climate controlled seat temperature dial signal and tachometer signal, Power is supplied

This is blower motor revolution control signal.

When blower motor receivers blower motor revolution control signal,

Power is supplied

When number of rotations correspond signal,

Ground is supplied

Then motor revolution is controlled.

When the ignition switch turned to ON or START position,

Power is supplied

Then ground is supplied

Then the climate controlled seat control unit recognizes seat cushion thermal electric device sensor signal.

When climate controlled control unit recognizes climate controlled switch "HEAT" signal and, seat cushion thermal electric device sensor signal,

Power is supplied

Then ground is supplied

When climate controlled control unit recognizes climate controlled switch "COOL" signal and, climate controlled seat cushion thermal electric device sensor signal, Power is supplied

Then ground is supplied

When the ignition switch turned to ON or START position,

Power is supplied

Then ground is supplied

Then the climate controlled seat control unit recognizes seatback thermal electric device sensor signal.

When climate controlled control unit recognizes climate controlled switch "HEAT" signal and climate controlled seatback thermal electric device sensor signal,

Power is supplied

ground is supplied

this climate controlled seatback thermal electric device generates heat wind is warmed.

When climate controlled control unit recognizes climate controlled switch "COOL" signal and climate controlled seatback thermal electric device sensor signal,

Power is supplied

ground is supplied

When climate controlled switch selects "HEAT",

Power is supplied

Ground is supplied

Then climate controlled seat switch "HEAT" indicator is energized.

When climate controlled switch select "COOL",

Power is supplied

Ground is supplied