Terminals and Reference Values for BCM
BCM TERMINALS AND REFERENCE VALUES
| Terminal | Wire Color | Item | Signal input/output | Condition | Voltage (V) (Approx.) | |
|---|---|---|---|---|---|---|
| 8 | G/OR | Detente switch signal | Input | Insert the key | Selector lever in P-position | 0 |
| Selector lever in other than P-position | Battery voltage | |||||
| 17 | BR/Y | Data link (RX line) | Output | - | - | |
| 18 | G/B | Data link (TX line) | Input | - | - | |
| 22 | R | Telescopic switch FR signal | Input | Telescoping switch | Forward operation | 0 |
| OFF | 5 | |||||
| 23 | W/R | Tilt switch DOWN signal | Input | Tilt switch | DOWN operation | 0 |
| OFF | 5 | |||||
| 26 | GY/R | Telescopic switch RR signal | Input | Telescoping switch | Backward operation | 0 |
| OFF | 5 | |||||
| 30 | PU | Monitor line (TX) | Output | - | - | |
| 31 | LG | Monitor line (RX) | Input | - | - | |
| 36 | Y/G | Tilt switch UP signal | Input | Tilt switch | UP operation | 0 |
| OFF | 5 | |||||
| 39 | G | Memory switch 1 signal | Input | Memory switch 1 | ON | 0 |
| OFF | 5 | |||||
| 43 | OR | Memory switch 2 signal | Input | Memory switch 2 | ON | 0 |
| OFF | 5 | |||||
| 46 | L/R | Tilt sensor signal | Input | Tilt position, top | 2 | |
| Tilt position, bottom | 4 | |||||
| 49 | P/L | Vehicle speed signal (2-pulse) | Input | When vehicle speed is approx. 40 km/h (25 MPH) | ||
| 50 | R/Y | Seat memory setting switch signal | Input | Setting switch | ON | 0 |
| OFF | 5 | |||||
| 53 | L/W | Tilt and telescopic sensor ground | - | Ignition switch ON | 0 | |
| 54 | B/Y | Tilt and telescopic sensor power supply | Input | - | 5 | |
| 55 | B/W | Ignition switch (START) | Input | Ignition switch (START position) | Battery voltage | |
| 56 | B | Ground | - | - | 0 | |
| 60 | L/OR | Ignition switch (ACC) | Input | Ignition switch (ACC or ON position) | Battery voltage | |
| 61 | R/B | Date line A-2 | Input/Output | - | - | |
| 62 | P/B | Telescopic sensor signal | Input | Telescoping position, top | 2 | |
| Telescoping position, bottom | 4 | |||||
| 67 | G/W | Date line A-3 | Input/Output | - | - | |
| 68 | W/B | Ignition switch (ON) | Input | Ignition switch (ON or START position) | Battery voltage | |
| 69 | PU/W | Key switch signal | Input | Insert the key (ON) | Battery voltage | |
| Remove the key (OFF) | 0 | |||||
| 101 | R/W | Telescopic motor FR signal | Output | Telescoping switch | Forward operation | Battery voltage |
| OFF | 0 | |||||
| 102 | W | Tilt motor DOWN signal | Output | Tilt switch | DOWN operation | Battery voltage |
| OFF | 0 | |||||
| 103 | Y | Tilt motor UP signal | Output | Tilt switch | UP operation | Battery voltage |
| OFF | 0 | |||||
| 104 | Y/B | Power supply for tilt and telescopic device | Input | - | Battery voltage | |
| 105 | Y/L | Battery power supply | Input | - | Battery voltage | |
| 106 | BR/Y | Power seat memory indicator 1 signal | Output | Indicator 1 | ON | 0 |
| OFF | Battery voltage | |||||
| 107 | R | Telescopic motor RR signal | Output | Telescoping switch | Backward operation | Battery voltage |
| OFF | 0 | |||||
| 112 | L/W | Power seat memory indicator 2 signal | Output | Indicator 2 | ON | 0 |
| OFF | Battery voltage | |||||
| 113 | B | Ground | - | Ignition switch ON | 0 | |
| 114 | B | Ground for tilt and telescoping device | - | Ignition switch ON | 0 | |
| 142 | W/R | Driver door switch signal | Input | Driver door open (ON) | 0 | |
| Driver door closed (OFF) | Battery voltage | |||||
| 148 | P | Data line A-1 | Input/Output | - | - | |