Engine Coolant Temperature Signal Inspection
Symptom: Water temperature gauge indication is malfunction.
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
- Start engine and select "METER A/C AMP" on CONSULT-II.
- Using "W TEMP METER" on "DATA MONITOR", compare the value of "DATA MONITOR" to the indication of water temperature gauge of combination meter.
DATA MONITORWater temperature gauge pointer Reference value of data monitor °C (°F) Hot Approx. 130 (266) Middle Approx. 70 - 105 (158 - 221) Cold Approx. 50 (122) Is the indication of water temperature gauge same as the value in the monitor?
OK: GO TO 2.
NG: Replace combination meter. [Perform self-diagnosis of ECM when the value in the monitor indicates 215°C (419°F). Then repair or replace the malfunction part.]
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
- Select "ENGINE" on CONSULT-II.
- Using "COOLAN TEMP/S" on "DATA MONITOR", print out the CONSULT-II screen.
- Select "METER A/C AMP" on CONSULT-II.
- Using "W TEMP METER" on "DATA MONITOR", compare the value of "DATA MONITOR" to that of the "COOLAN TEMP/S".
OK or NG
OK: Perform self-diagnosis of ECM. Refer to "CONSULT-II FUNCTION (ENGINE) " (for VQ35DE) or "CONSULT-II FUNCTION (ENGINE) " (for VK45DE).
NG: Replace unified meter and A/C amp.