Operation Procedure

Touch "DATA MONITOR" on "SELECT DIAG MODE" screen.

NOTE: When malfunctions detected, CONSULT-II performs "REAL-TIME DIAGNOSIS". Also, any malfunction detected while in this mode will be displayed at real time.
Fig 1: Consult-II SELECT DIAG MODE Display Screen
G04083861Courtesy of NISSAN MOTOR CO., U.S.A.

Display Items List 

DISPLAY ITEMS LIST

X: Standard, -: Not applicable, : Option
Monitored item (Unit) Select Monitor Item Remarks
ECU INPUT SIGNALS MAIN SIGNALS SELECTION FROM MENU
VHCL/S SE-A/T (km/h) X X   Revolution sensor
VHCL/S SE-MTR (km/h) X -    
ACCELE POSI (0.0/8) X -   Accelerator pedal position signal
THROTTLE POSI (0.0/8) X X   Degree of opening for accelerator recognized by the TCM
For fail-safe operation, the specific value used for control is displayed.
CLSD THL POS (ON/OFF) X -   Signal input with CAN communications
W/O THL POS (ON/OFF) X -  
BRAKE SW (ON/OFF) X -   Stop lamp switch
GEAR - X   Gear position recognized by the TCM updated after gear-shifting
ENGINE SPEED (rpm) X X    
TURBINE REV (rpm) X X    
OUTPUT REV (rpm) X X    
GEAR RATIO - X    
TC SLIP SPEED (rpm) - X   Difference between engine speed and torque converter input shaft speed
F SUN GR REV (rpm) - -    
F CARR GR REV (rpm) - -    
ATF TEMP SE 1 (V) X -    
ATF TEMP SE 2 (V) X -    
ATF TEMP 1 (°C) - X    
ATF TEMP 2 (°C) - X    
BATTERY VOLT (V) X -    
ATF PRES SW 1 (ON/OFF) X X   (for FR/B solenoid)
ATF PRES SW 2 (ON/OFF) X X   (for LC/B solenoid)
ATF PRES SW 3 (ON/OFF) X X   (for I/C solenoid)
ATF PRES SW 5 (ON/OFF) X X   (for D/C solenoid)
ATF PRES SW 6 (ON/OFF) X X   (for HLR/C solenoid)
PNP SW 1 (ON/OFF) X -    
PNP SW 2 (ON/OFF) X -    
PNP SW 3 (ON/OFF) X -    
PNP SW 4 (ON/OFF) X -    
1 POSITION SW (ON/OFF) X -    
SLCT LVR POSI - X   Selector lever position is recognized by the TCM.
For fail-safe operation, the specific value used for control is displayed.
OD CONT SW (ON/OFF) X -   Not mounted but displayed.
POWER SHIFT SW (ON/OFF) X -  
HOLD SW (ON/OFF) X -  
MANU MODE SW (ON/OFF) X -    
NON M-MODE SW (ON/OFF) X -    
UP SW LEVER (ON/OFF) X -    
DOWN SW LEVER (ON/OFF) X -    
SFT UP ST SW (ON/OFF) - -   Not mounted but displayed.
SFT DWN ST SW (ON/OFF) - -  
ASCD.OD CUT (ON/OFF) - -    
ASCD.CRUISE (ON/OFF) - -    
ABS SIGNAL (ON/OFF) - -    
ACC OD CUT (ON/OFF) - -   ICC (intelligent cruise control)
ACC SIGNAL (ON/OFF) - -  
TCS GR/P KEEP (ON/OFF) - -    
TCS SIGNAL 2 (ON/OFF) - -    
TCS SIGNAL 1 (ON/OFF) - -    
TCC SOLENOID (A) - X    
LINE PRES SOL (A) - X    
I/C SOLENOID (A) - X    
FR/B SOLENOID (A) - X    
D/C SOLENOID (A) - X    
HLR/C SOL (A) - X    
ON OFF SOL (ON/OFF) - -   LC/B solenoid
TCC SOL MON (A) - -    
L/P SOL MON (A) - -    
I/C SL MON (A) - -    
FR/B SOL MON (A) - -    
D/C SOL MON (A) - -    
HLR/C SOL MON (A) - -    
ON OFF SOL MON (ON/OFF) - -   LC/B solenoid
P POSI IND (ON/OFF) - -    
R POSI IND (ON/OFF) - -    
N POSI IND (ON/OFF) - -    
D POSI IND (ON/OFF) - -    
4TH POSI IND (ON/OFF) - -    
3RD POSI IND (ON/OFF) - -    
2ND POSI IND (ON/OFF) - -    
1ST POSI IND (ON/OFF) - -    
MANU MODE IND (ON/OFF) - -    
POWER M LAMP (ON/OFF) - -    
F-SAFE IND/L (ON/OFF) - -    
ATF WARN LAMP (ON/OFF) - -   Not mounted but displayed
BACK-UP LAMP (ON/OFF) - -    
STARTER RELAY (ON/OFF) - -    
PNP SW3 MON (ON/OFF) - -    
C/V CLB ID1 - -    
C/V CLB ID2 - -    
C/V CLB ID3 - -    
UNIT CLB ID1 - -    
UNIT CLB ID2 - -    
UNIT CLB ID3 - -    
TRGT GR RATIO - -    
TRGT PRES TCC (kPa) - -    
TRGT PRES L/P (kPa) - -    
TRGT PRES I/C (kPa) - -    
TRGT PRE FR/B (kPa) - -    
TRGT PRES D/C (kPa) - -    
TRG PRE HLR/C (kPa) - -    
SHIFT PATTERN - -    
DRV CST JUDGE - -    
START RLY MON - -    
NEXT GR POSI - -    
SHIFT MODE - -    
MANU GR POSI - -    
VEHICLE SPEED (km/h) - X   Vehicle speed recognized by the TCM.
Voltage (V) - -   Displays the value measured by the voltage probe.
Frequency (Hz) - -   The value measured by the pulse probe is displayed.
DUTY-HI (high) (%) - -  
DUTY-LOW (low) (%) - -  
PLS WIDTH-HI (ms) - -  
PLS WIDTH-LOW (ms) - -