Lighting Switch Signal Inspection
- CHECK BCM INPUT SIGNAL
- Select "BCM" on CONSULT-II.
- With "DATA MONITOR" of "BUZZER", confirm "LIGHT SW 1ST" when the lighting switch is operated.
"LIGHT SW 1ST"
Lighting switch ON (1st position) : ON
Lighting switch OFF : OFF
OK or NG
OK : INSPECTION END
NG : Check the lighting switch. Refer to "COMBINATION SWITCH INSPECTION ".