Removal And Installation: Removal
- Set the temperature at 18°C (60°F), and then disconnect the battery negative cable.
- Use a refrigerant collecting equipment (for HFC-134a) to discharge refrigerant.
- Remove the mounting bolt, then remove the low-pressure pipe 2 and high-pressure pipe 3. Refer to REMOVAL AND INSTALLATION OF LOW-PRESSURE PIPE 2 AND HIGH-PRESSURE PIPE 3
.CAUTION: Seal connection opening of piping with a cap or vinyl tape to avoid exposure to atmosphere.
- Slide the evaporator to passenger side, then remove the intake sensor.