Fail-Safe Function
- If a communication error exists between unified meter and A/C amp. and A/C and AV switch for 30 seconds or longer, air conditioner is controlled under following conditions:
- Compressor: ON
- Air outlet: AUTO
- Air inlet: FRE (Fresh)
- Blower fan speed: AUTO
- Set temperature: Setting before communication error occurs.