System Description: Notes
The warning chime is controlled by the smart entrance control unit.
The warning chime is located in the smart entrance control unit. Power is supplied at all times
- through 7.5A fuse [No. 24, located in fuse block (J/B)]
- to smart entrance control unit terminal 49 and
- to key switch terminal 2,
- through 10A fuse (No. 61, located in the fuse and fusible link box)
- to tail lamp relay terminals 1 and 3.
When the ignition switch in the ON or START position, power is supplied
- through 7.5A fuse [No. 11, located in the fuse block (J/B)]
- to smart entrance control unit terminal 27.
Ground is supplied
- to smart entrance control unit terminals 43 and 64
- through body grounds M77 and M111.
When a signal, or combination of signals, is received by the smart entrance control unit, the warning chime will sound.