With Consult-II
- Turn ignition switch to "ON" position. (Do not start engine.)
- Select "DATA MONITOR" mode for "ENGINE" with CONSULT-II.
- Start engine.
- Maintain the following conditions for at least 2 consecutive seconds.
THRTL POS SEN: More than 1.2V
- If DTC is detected, go to "DIAGNOSTIC PROCEDURE "