Component Tests: THERMOSWITCH

  1. Remove thermoswitch.
  2. Check thermoswitch for proper operation. Operating temperature: OFF to ON 90°C (194°F).
  3. If no good, replace thermoswitch.
Fig 1: Checking Thermoswitch
G00152420Courtesy of NISSAN MOTOR CO., U.S.A.