DTC Setting Condition
| Item | DTC setting condition |
|---|---|
| Main Action | Signal monitoring |
| Prerequisite Condition | Battery Voltage 11 ~ 16V Downstream oxygen temperature 350 ~ 650°C Intake air temperature -7°C or higher |
| Fault Determination | If the internal resistance of the downstream oxygen sensor is higher than the standard |
| Diagnosis Time | 10 seconds |
| Threshold Value for Warning Light | 2nd drive cycle |