| Case 1 |
Main Action |
- Level 2 process monitoring
|
- Contact resistance in connectors
- Faulty ECM
|
| Prerequisite Condition |
- Ignition switch is turned "ON" or engine is running with speed over 32rpm.
|
| Threshold Value |
- Actual value is higher or lower than allowable range.
|
| Diagnosis Time |
|
| Case 2 |
Main Action |
- Level 2 process monitoring
|
| Prerequisite Condition |
- Engine is running with speed over 32rpm.
|
| Threshold value |
- Torque difference between actual and set-point value is higher than allowable range.
|
| Diagnosis Time |
|
| Case 3 |
Main Action |
- Level 2 process monitoring
|
| Prerequisite Condition |
- Engine is running with speed over 32rpm.
|
| Threshold Value |
- Engine speed is too high when ETC limp home is active.
- Engine speed is higher than 1760rpm.
|
| Diagnosis Time |
|
| Case 4 |
Main Action |
- Check RAM Area/communication connections
|
| Prerequisite Condition |
- Ignition switch is turned "ON".
|
| Threshold value |
- RAM test/Checksum/SPI communication failure
|
| Diagnosis Time |
|
| Case 5 |
Main Action |
- Level 3 process monitoring
|
| Prerequisite Condition |
- Ignition switch is turned "ON".
|
| Threshold value |
- RAM/ROM error on micro-controller checksum check
- RAM/ROM error on communication between main controller and monitoring unit
- Process monitoring test calculation failed
|
| Diagnosis Time |
|
| MIL On Condition |
|