Repair Procedures: Inspection
- Turn the ignition switch OFF
- Disconnect the CCV connector
- Measure resistance between the CCV terminal 1 and 2
- Check that the resistance is within the specification.
Specification: Refer to " SPECIFICATION "
- Disconnect the vapor hose connected with the canister from the CCV
- Connect a vacuum pump to the nipple
- Ground the CCV control line and apply battery voltage to the CCV power supply line
- Apply vacuum and check the valve operation.
Specification: Vacuum maintained