Component Inspection
WARNING: This page is about a different variant/trim than selected.
■ Check Generator Position Sensor
- IG key "OFF".
- Disconnect SAFETY PLUG* and then Wait for more than 5 minutes.
- Disconnect HSG* connector.
- Measure the resistance of HSG Position Sensor* below.
Reference Value (23°C)
Terminal (+) Probe ↔ (-) Probe Resistance "HYBRID STARTER & GENERATOR MOTOR_Resolver" Component connector (+) ↔ (-) 10.53Ω~12.87Ω "SNSR1" ↔ "SNSR3" 28.8Ω~35.2Ω "SNSR2" ↔ "SNSR4" 24.3Ω~29.7Ω (+) ↔ Shield Over 10MΩ (+) ↔ Ground Over 10MΩ (-) ↔ Shield Over 10MΩ (-) ↔ Ground Over 10MΩ - Is the measured resistance within reference value?
YES
- Fault is intermittent caused by Poor Contact in HSG Position Sensor*'s connector or GCU (HPCU)*'s connector.
→ Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
→ Repair or replace as necessary, go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Check the mounting state of HSG Position Sensor*.
- Substitute with a known-good HSG* and then check for proper operation.
→ If the problem is corrected, replace HSG*.
→ Go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NOTE:
SAFETY PLUG*: "BMS ASSEMBLY_MAIN BATTERY SERVICE PLUG"
HSG*: "HYBRID STARTER & GENERATOR MOTOR"
HSG Position Sensor*: "HYBRID STARTER & GENERATOR MOTOR_Resolver"
GCU (HPCU)*: "HYBRID POWER CONTROL UNIT_HPCU"
HSG*: "HYBRID STARTER & GENERATOR MOTOR"
HSG Position Sensor*: "HYBRID STARTER & GENERATOR MOTOR_Resolver"
GCU (HPCU)*: "HYBRID POWER CONTROL UNIT_HPCU"
NOTE:
After Generator (HSG) is replaced or reinstalled, must perform the following.
- Perform "Motor/HSG Resolver Calibration" procedure in "HCU/LDC" system →"Vehicle S/W Management"
- Fill the coolant, and then perform "Actuation Test" → [EWP Actuation] and circulate the coolant.
WARNING:
Non-compliance with the following instructions can induce death or injury caused by electric shock.
- Carefully read and follow service information instructions.
- Wear insulated gloves, safety glasses and use insulated tools for your safety.
- Turn IG key switch off and disconnect ground cable of auxiliary battery and remove the safety plug.
- Wait for more than 5 minutes so that the inverter capacitor can be naturally discharged.
- Check the high voltage terminal on the power relay assembly is lower than 30V.