Current data Analysis
WARNING: This page is about a different variant/trim than selected.
- IG key "ON"/Ready, Transmission Shift Lever "P" range.
- Select "Current Data" with GDS.
- Operate the vehicle within DTC Enable conditions in General information.
- Monitor "Generator (HSG) Temperature" parameter.
Reference Data
GENERATOR (HSG) TEMPERATURE REFERENCENormal □ Generator (HSG) Temperature: -20°C~185°C - Is the displayed current data normal?
YES
- Fault is intermittent caused by Poor Contact in Generator (HSG) Temperature Sensor*'s connector or GCU (HPCU)*'s connector, or GCU (HPCU)* memory was not cleared after repair.
- Go to "WIRING INSPECTION " procedure.
NO
- Go to "COMPONENT INSPECTION " procedure.
NOTE:
HSG Temperature Sensor*: "HYBRID STARTER & GENERATOR MOTOR_Motor TEMP. Sensor"
GCU (HPCU)*: "HYBRID POWER CONTROL UNIT_HPCU"
GCU (HPCU)*: "HYBRID POWER CONTROL UNIT_HPCU"