Repair Procedures: Inspection
- Immerse the thermostat in water and gradually heat the water.
- Check the valve opening temperature.
Valve opening temperature:
88 ± 2°C (109.4 ± 3.6°F)
Full opening temperature: 100°C (212°F)
If the valve opening temperature is not as specified, replace the thermostat.
- Check the valve lift.
Valve lift: 10 mm (0.3937 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.