LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2017 >> Azera Base >> Repair and Diagnosis >> Accessories & Equipment >> Heated Glass/Defoggers >> Rear Glass Defogger System >> Rear Glass Defogger Printed Heater >> Repair Procedures >> Inspection >> Notes

Repair Procedures: Inspection: Notes

CAUTION: Wrap tin foil around the end of the voltmeter test lead to prevent damaging the heater line. Apply finger pressure on the tin foil, moving the tin foil along the grid line to check for open circuits.
Fig 1: Wrapping Tin Foil Around End Of Voltmeter Test Lead
G12093068Courtesy of HYUNDAI MOTOR AMERICA
  1. Turn on the defogger switch and use a voltmeter to measure the voltage of each heater line at the glass center point. If a voltage of approximately 6V is indicated by the voltmeter, the heater line of the rear window is considered satisfactory.
    Fig 2: Measuring Voltage Of Each Heater Line At Glass Center Point
    G12093069Courtesy of HYUNDAI MOTOR AMERICA
  2. If a heater line is burned out between the center point and (+) terminal, the voltmeter will indicate 12V.
    Fig 3: Checking Heater Line Burned Out Between Center Point And (+) Terminal
    G12093070Courtesy of HYUNDAI MOTOR AMERICA
  3. If a heater line is burned out between the center point and (-) terminal, the voltmeter will indicate 0V.
    Fig 4: Checking Heater Line Burned Out Between Center Point And (-) Terminal
    G12093071Courtesy of HYUNDAI MOTOR AMERICA
  4. To check for open circuits, slowly move the test lead in the direction that the open circuit seems to exist. Try to find a point where a voltage is generated or changes to 0V. The point where the voltage has changed is the open-circuit point.
    Fig 5: Checking Open-Circuit Point
    G12093072Courtesy of HYUNDAI MOTOR AMERICA
  5. Use an ohmmeter to measure the resistance of each heater line between a terminal and the center of a grid line, and between the same terminal and the center of one adjacent heater line. The section with a broken heater line will have a resistance twice as that in other sections. In the affected section, move the test lead to a position where the resistance sharply changes.
Fig 6: Measuring Resistance Of Each Heater Line Between Terminal And Center Of Grid Line
G12093073Courtesy of HYUNDAI MOTOR AMERICA