Signal Circuit Inspection
■ Check voltage
- IG "OFF" and disconnect HO2S(B1/S2) connector.
- IG "ON".
- Measure voltage between signal terminal of HO2S(B1/S2) harness connector and chassis ground.
Specification: Approx. 0.8~1.2V
- Is the measured voltage within specification?
YES
- Go to "Ground Circuit Inspection " procedure below.
NO
- Repair open in harness, and go to "Verification of Vehicle Repair " procedure.