LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2016 >> Azera Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System >> Evaporator Temperature Sensor >> Repair Procedures >> Inspection

Repair Procedures: Inspection

  1. Ignition "OFF".
  2. Disconnect evaporator temperature sensor.
  3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.
    Fig 1: Measuring Resistance Between Evaporator Temperature Sensor Terminal 1 And 2
    G10369800Courtesy of HYUNDAI MOTOR AMERICA

Specification 

EVAPORATOR CORE TEMPERATURE SPECIFICATION

Evaporator core temperature [°C(°F)] Resistance[KΩ] Voltage[V]
-20(-4) 70.04 3.50
-10(14) 43.35 2.96
0(32) 27.62 2.40
10(50) 18.07 1.88
20(68) 12.11 1.44
30(86) 8.30 1.08
40(104) 5.81 0.81
50(122) 4.15 0.61