LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2014 >> Veloster Base, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 29 (Heater System) >> Temperature Control Actuator >> Repair Procedures >> Inspection

Repair Procedures: Inspection

WARNING: This page is about a different car, the 2012 Hyundai Veloster. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition "OFF"
  2. Disconnect the connector of temperature control actuator.
  3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 4 and grounding terminal 3

    Verify that the temperature control actuator operates to the cool position when connecting in the reverse.

    Fig 1: Verifying Temperature Control Actuator Operates To Cool Position When Connected In Reverse
    G08811996Courtesy of HYUNDAI MOTOR AMERICA
  4. Check the voltage between terminals 6 and 7.
    VOLTAGE SPECIFICATION

    Door position Voltage (6-7) Error detecting
    Max. cooling 0.45 ± 0.15V Low voltage: 0.1V or less
    Max. heating 4.55 ± 0.15V High voltage: 4.9V or more

    It will feedback current position of actuator to controls.

  5. If the measured voltage is not specification, substitute with a known-good temperature control actuator and check for proper operation.
  6. If the problem is corrected, replace the temperature control actuator.