LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2014 >> Equus Ultimate >> Repair and Diagnosis >> Electrical >> Starter >> Starting System >> Starter Relay >> Repair procedures >> Inspection

Repair procedures: Inspection

  1. Disconnect the battery negative terminal.
  2. Remove the fuse box cover.
  3. Remove the starter relay (A).
    Fig 1: Identifying Starter Relay
    G09789230Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  4. Using an ohmmeter, check that there is continuity between each terminal.
    Terminal Continuity
    30 - 87 NO
    85 - 86 YES
  5. Apply 12V to terminal 85 and ground to terminal 86.

    Check for continuity between terminals 30 and 87.

    Fig 2: Checking Continuity Between Starter Relay Terminals
    G09789231Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  6. If there is no continuity, replace the starter relay.
  7. Install the starter relay.
  8. Install the fuse box cover.