AMBIENT TEMPERATURE SPECIFICATIONS
| Ambient temperature [°C (°F)] | Resistance between terminals 1 and 2 (kΩ) |
|---|---|
| -30 (-22) | 480.41 |
| -20 (-4) | 271.21 |
| -10 (14) | 158.18 |
| 10 (32) | 95.10 |
| 10 (50) | 58.80 |
| 20 (68) | 37.32 |
| 30 (86) | 23.76 |
| 40 (104) | 16.13 |
| 50 (122) | 10.95 |
- 4. If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
- 5. If the problem is corrected, replace the ambient temperature sensor.