LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2013 >> Genesis 3.8 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System >> Ambient Sensor >> Repair Procedures >> Inspection

Repair Procedures: Inspection

  1. Ignition "OFF"
  2. Disconnect ambient temperature sensor.
  3. Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.
    RESISTANCE SPECIFICATION

    Ambient temperature [°C(°F)] Resistance between terminals 1 and 2 (kΩ)
    -30(14) 480.41 ± 3%
    -2032) 271.21± 3%
    -10(50) 158.18± 3%
    0(68) 95.10± 3%
    10(50) 58.80± 3%
    20(68) 37.32± 3%
    30(86) 24.26± 3%
    40(104) 16.13± 3%
    50(122) 10.95± 3%
    Fig 1: Checking Resistance Of Ambient Temperature Sensor Between Terminals 1 And 2
    G08838947Courtesy of HYUNDAI MOTOR AMERICA
  4. If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
  5. If the problem is corrected, replace the ambient temperature sensor.