DTC DETECTING CONDITIONS

Item Detecting Condition Possible Cause
DTC Strategy
  • Check HO2S Signal Amplitude
  • Leak in intake or exhaust system
  • Poor connection or damaged harness
  • HO2S contamination
Enable Conditions
  • See catalyst diagnosis (P0420) activation condition
  • No relevant failure
  • 11V< Battery voltage<16V
Threshold Value
  • Integral (Lambda signal amplitude measured / Lambda signal amplitude of a slow sensor) > 1.0
Diagnostic Time
  • 25 lambda controller cycle
Mil On Condition
  • 2 Driving Cycles