Measuring Resistance
- Disconnect the cruise control switch connector from the control switch.
- Measure resistance between terminals on the control switch when each function switch is ON (switch is depressed)
Function switch Terminal Resistance CANCEL 3-4 0Ω SET/- 3-4 220Ω RES/+ 3-4 1130Ω ON/OFF 1-3 3900Ω - If not within specification, replace switch.