VFS (Variable Force Solenoid) Valve: Installation
- Install the solenoid valve (8).CAUTION: Apply ATF oil or White Vaseline to the O-ring to prevent damage.
- Connect the solenoid valve connector (A).CAUTION: When connecting the solenoid valve connector, check the connector for rust, dirt, or oil, then reconnect it.
- Install the valve body. (Refer to VFS (VARIABLE FORCE SOLENOID) VALVE )
Tightening torque :
10 ~ 12 Nm (1.0 ~ 1.2 kgf.m, 7 ~ 8 lb-ft)
- Install the oil filter.
Tightening torque :
10 ~ 12 Nm (1.0 ~ 1.2 kgf.m, 7 ~ 8 lb-ft)
- Continue to apply liquid gasket at application points at the oil pan with Ø2.5 mm (0.098 in) thickness.
Liquid gasket Part name : Threebond 1281B
- Tighten the mounting bolt with the specified torque after installing the oil pan.
Tightening torque:
10 ~ 12 Nm (1.0 ~ 1.2 kgf.m, 7 ~ 8 lb-ft)
- Install the drain plug.
Tightening torque:
40 ~ 50 Nm (4.0 ~ 5, 0 kgf.m, 28.9 ~ 36.2 lb-ft)
- Installation is the reverse of the removal.