Component Inspection
- Check resistance of IATS
- IG "OFF" and disconnect IATS connector.
- Measure resistance between terminal 4 and 5 of IATS connector after checking out the temperature of IATS with scantool
Specification
RESISTANCE SPECIFICATIONTemp. (°C/°F) Resistance (kΩ) Temp. (°C/°F) Resistance (kΩ) -40(-40) 95.95 ~ 105.78 20(68) 3.42~3.61 -20(-4) 27.4 ~ 29.77 40(104) 1.43~1.5 0(32) 9.08 ~ 9.72 60(140) 0.66~0.69 10(50) 5.49 ~ 5.83 80(176) 0.33~0.34 - Is the measured resistance within specification?
YES
- Go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Substitute with a known - good IATS and check for proper operation. If the problem is corrected, replace IATS and go to "VERIFICATION OF VEHICLE REPAIR " procedure.