Terminal And Connector Inspection
- Many malfunctions in the electrical system are caused by poor harness (es) and terminals. Faults can also be caused by interference from other electrical systems and mechanical or chemical damage.
- Check the following conditions:
- Check for damaged harness and terminals: contact resistance, oxidation, bent or broken terminals.
- Check for poor connection between ECM and component: backed out terminal, improper mating, broken locks and poor terminal to wire connection.NOTE: Using a suitable male pin to ensure that contact in sockets is good. The pin should remain in position when pulled gently.
- Has a problem been found?
YES:
- Repair as necessary and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO:
- Go to "M/F SW SIGNAL CIRCUIT INSPECTION " procedure.