| DTC Strategy |
|
- Open or short of pressure sensor circuit
- Faulty pressure sensor
- Faulty HECU
|
| Monitoring Period |
- After Pressure sensor initialization.
- No under voltage
- No pumps are running.
- No BLS-signal is set.
|
| Enable Conditions |
- The pressure sensor-offset value must be in the range of ± 15 bar. A failure is detected if this range is exceeded.
|
| Fail Safe |
- Reduced function caused by faulty pressure sensor signal.
- Sensor failure outside the ABS control cycle
- Only the ABS/ESC functions are inhibited, allow the EBD. The ABS/ESC warning lamps are activated and the EBD warning lamp is not activated.
- Sensor failure inside the ABS control cycle
- Inhibit the ESC control, allow the EBD. The ESC warning lamps are activated. After the control, the ABS functions are inhibited. The ABS warning lamps are activated.
|