P0707 Transmission Range Sensor Circuit Low Input: General Description
The Transaxle Range Switch sends the shift lever position information to the TCM (PCM) using a 12V (battery voltage) signal. When the shift lever is in the D (Drive) position the output signal of Transaxle Range Switch is 12V and in all other positions the voltage is 0 V. The TCM (PCM) judges the shift lever position by reading all signals, for the Transaxle Range Switch, simultaneously.