| DTC Strategy |
|
- Open or short of pressure sensor circuit
- Faulty pressure sensor
- Faulty HECU
|
| Case1 |
Monitoring Period |
|
| Enable Conditions |
- A sensor supply failure is detected if Sensor Supply Voltage > 5.3V or Sensor Supply Voltage < 4.7V for t >= 60ms
|
| Case2 |
Monitoring Period |
|
| Enable Conditions |
- A Fault is set if the DSO signal is voltage of DSO > 4.7V or voltage of DSO < 0.3V for a time t >= 100ms.
- DSO : original pressure value.
|
| Case3 |
Monitoring Period |
|
| Enable Conditions |
- A Fault is set if the DSI signal is voltage of DSI > 4.7V or voltage of DSI < 0.3V for a time t >= 100ms.
- DSI: inverted pressure value.
|
| Case4 |
Monitoring Period |
|
| Enable Conditions |
- A Fault is set if the voltage of DSO + DSI > 5.5V or voltage of DSO + DSI < 4.5V for a time t >= 100ms.
- DSO : original pressure value.
- DSI: inverted pressure value.
|
| Case 5 |
Monitoring Period |
|
| Enable Conditions |
|
| Fail Safe |
- No Pressure Signal available.
- Sensor failure outside the ABS control cycle
- Only the ABS/ESC functions are inhibited, allow the EBD. The ABS/ESC warning lamps are activated and the EBD warning lamp is not activated.
- Sensor failure inside the ABS control cycle
- Inhibit the ESC control, allow the EBD. The ESC warning lamps are activated. After the control, the ABS functions are inhibited. The ABS warning lamps are activated.
|