LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2009 >> Santa Fe GLS, AWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Control System (Fuel System (2.7)) >> Purge Control Solenoid Valve (PCSV) >> Description

Purge Control Solenoid Valve (PCSV): Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.

Fig 1: Identifying Purge Control Solenoid Valve
G06216331Courtesy of HYUNDAI MOTOR CO.