Diagnostic Trouble Code Table
DIAGNOSTIC TROUBLE CODE CHART
| No. | Code | Item | MIL | Remark |
|---|---|---|---|---|
| 1 | P0605 | Internal Control Module Read Only Memory (ROM) Error | • | |
| 2 | P0707 | TRANSAXLE RANGE SWITCH CIRCUIT LOW INPUT | • | |
| 3 | P0708 | TRANSAXLE RANGE SWITCH CIRCUIT HIGH INPUT | • | |
| 4 | P0711 | TRANSAXLE FLUID TEMPERATURE SENSOR RATIONALITY | • | |
| 5 | P0712 | TRANSAXLE FLUID TEMPERATURE SENSOR CIRCUIT LOW INPUT | • | |
| 6 | P0713 | TRANSAXLE FLUID TEMPERATURE SENSOR CIRCUIT HIGH INPUT | • | |
| 7 | P0716 | A/T INPUT SPEED SENSOR RATIONALITY | • | |
| 8 | P0717 | A/T INPUT SPEED SENSOR CIRCUIT - OPEN or SHORT (GND) | • | |
| 9 | P0722 | A/T OUTPUT SPEED SENSOR CIRCUIT - OPEN or SHORT (GND) | • | |
| 10 | P0731 | GEAR 1 INCORRECT RATIO | • | |
| 11 | P0732 | GEAR 2 INCORRECT RATIO | • | |
| 12 | P0733 | GEAR 3 INCORRECT RATIO | • | |
| 13 | P0734 | GEAR 4 INCORRECT RATIO | • | |
| 14 | P0741 | TORQUE CONVERTER CLUTCH STUCK OFF | • | |
| 15 | P0742 | TORQUE CONVERTER CLUTCH STUCK ON | • | |
| 16 | P0743 | TORQUE CONVERTER CLUTCH CONTROL SOLENOID VALVE - OPEN or SHORT (GND) | • | |
| 17 | P0748 | VFS SOLENOID VALVE CIRCUIT - OPEN or SHORT (GND) | X | |
| 18 | P0750 | ON/OFF (SCSV-A) SOLENOID VALVE CIRCUIT - OPEN or SHORT (GND) | • | |
| 19 | P0755 | PCSV-A (OD & LR ) SOLENOID VALVE CIRCUIT - OPEN or SHORT (GND) | • | |
| 20 | P0760 | PCSV-B (2-4 SOLENOID VALVE) CIRCUIT - OPEN or SHORT (GND) | • | |
| 21 | P0765 | PCSV-C (UD) SOLENOID VALVE CIRCUIT - OPEN or SHORT (GND) | • | |
| 22 | P0880 | TCM POWER SIGNAL ERROR | • | |
| 23 | U0001 | CAN Communication Malfunction | • | |
| 24 | U0100 | CAN MI-COM OR CIRCUIT MAL | • |