Charging System

WARNING: This page is about a different car, the 2006 Hyundai Tucson. However, it is still accessible from the selected car via links, so may be relevant.
CHARGING SYSTEM SPECIFICATIONS

Item Specifications
2.7 2.0
Alternator Type Internal sensing
Rated voltage 13.5V, 120A 13.5V, 90A
Speed 1,000 ~ 18,000 rpm
Voltage regulator Electronic built-in type
Regulator setting voltage 14.55 +/- 0.2V 14.55 +/- 0.2V
Temperature compensation -3.5 +/- 1mV/°C -7 +/- 3mV/°C
Battery Type MF 70 AH MF 60 AH
Cold cranking amperage at-18°C (0°F) 600A 550A
Reserve capacity 113min 92min
Specific gravity at 20°C (77°F) 1.280 +/- 0.01 1.280 +/- 0.01
NOTE:
  • COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
  • RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7° C (80° F)