[Connector C30-3]
ECM TERMINAL FUNCTION DESCRIPTION - CONNECTOR C30-3
| PIN NO. | Description | Connected to | Remark |
|---|---|---|---|
| 1 | MAFS signal input | MAFS | |
| 2 | Not connected | - | |
| 3 | Not connected | - | |
| 4 | Not connected | - | |
| 5 | Not connected | - | |
| 6 | Not connected | - | |
| 7 | Not connected | - | |
| 8 | CKPS signal input | CKPS | |
| 9 | Not connected | - | |
| 10 | TPS supply | TPS | |
| 11 | Not connected | - | |
| 12 | Not connected | - | |
| 13 | Not connected | - | |
| 14 | Not connected | - | |
| 15 | Not connected | - | |
| 16 | Not connected | - | |
| 17 | MAFS ground | MAFS ground | |
| 18 | Not connected | - | |
| 19 | TPS signal input | TPS | |
| 20 | TPS ground | TPS | |
| 21 | CKPS ground | CKPS | |
| 22 | IATS signal input | IATS | |
| 23 | IATS ground | IATS | |
| 24 | ECTS signal input | ECTS | |
| 25 | ECTS ground | ECTS | |
| 26 | Power steering load input | Power steering switch | |
| 27 | Not connected | - | |
| 28 | Not connected | - | |
| 29 | Knock sensor1, input A (CYL 1/3/5) | Knock sensor1 (CYL 1/3/5) | |
| 30 | Knock sensor1, input B (CYL 1/3/5) | Knock sensor1 (CYL 1/3/5) | |
| 31 | Knock sensor2, input A (CYL 2/4/6) | Knock sensor2 (CYL 2/4/6) | |
| 32 | Knock sensor2, input B (CYL 2/4/6) | Knock sensor2 (CYL 2/4/6) | |
| 33 | Injector output (CYL.1) | Injector (CYL. 1) | |
| 34 | Injector output (CYL.2) | Injector (CYL.2) | |
| 35 | Injector output (CYL.3) | Injector (CYL.3) | |
| 36 | Injector output (CYL.4) | Injector (CYL.4) | |
| 37 | Injector output (CYL.5) | Injector (CYL.5) | |
| 38 | Injector output (CYL.6) | Injector (CYL.6) | |
| 39 | Not connected | - | |
| 40 | Not connected | - | |
| 41 | Not connected | - | |
| 42 | Canister purge sol. Valve control | Canister purge sol. Valve | |
| 43 | Not connected | - | |
| 44 | Not connected | - | |
| 45 | VIS sol. Output | Variable Intake control System sol. 1 | |
| 46 | ISCA PWM output 2 | ISCA | |
| 47 | ISCA PWM output 1 | ISCA | |
| 48 | Knock sensor shield | Knock sensor | |
| 49 | Not connected | - | |
| 50 | Not connected | - | |
| 51 | Not connected | - | |
| 52 | VIS sol2. Output | Variable Intake control System sol. 2 |