LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 2005 >> Accent GT, Standard >> Repair and Diagnosis >> Engine Performance >> Ignition System >> General Information - Charging System, Ignition & Starting System >> Specification >> Charging System

Charging System

CHARGING SYSTEM SPECIFICATIONS

Items Specifications
Alternator 
Type Battery voltage sensing
Rated voltage 13.5V, 90A
Speed in use 1000 ~ 18,000 RPM
Voltage regulator Electronic built-in type
Regulator setting voltage 14.55 +/- 0.2V
Temperature compensation -10 +/- 3 mV/°C
Battery 
Type MF55AH
Cold cranking amperage [at -18° (0°F)] 500A
Reserve capacity 85min
Specific gravity [at 25°C (77°F)] 1,280 +/- 0.01
COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2 or greater at a specified temperature.
REVERSE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5 at 26.7°C (80°F)