Cruise Control System: Specifications
Cruise Control System General Specifications
| Speed control module | |
| Operating voltage range | DC 10 - 16 V |
| Operating temperature | -30 ± 75°C (-22 ± 167°F) |
| Voltage drop between unit and actuator | 0.4 V |
| Operating speed range | Low speed limit: 40 ± 2 km/h (25 ± 1.3 mph) High speed limit: 160 ± 2 km/h (99 ± 1.3 mph) |
| Actuator | |
| Rated voltage | DC 12 V |
| Operating temperature | -30 ± 90°C (-22 ± 194°F) |
| Operating consumption | 3A or less (at 12V 20°C) |
| Insulating resistance | 1MΩ or less (at 500V megger) |
| Cruise main switch | |
| Rated voltage | DC 12 V |
| Operating force | 0.3 - 1.0 kg |
| Voltage drop | 0.15 V or less |
| Stop lamp switch | |
| Rated voltage | DC 12 V |
| Rated load | |
| Stop lamp | 27 x 5 W (lamp load) |
| Cruise control | 0.1 - 0.5 A (relay load) |
| Insulating resistance | 1 MΩ or more |