Heated Oxygen Sensor (Ho2S)
Testing requires use of scan tool. See related DTC in appropriate TESTS W/CODES article.
IAT SENSOR TEMPERATURE-TO-VOLTAGE SPECIFICATIONS (1)
| Temperature °F (°C) | Volts | ||
|---|---|---|---|
| 32 (0) | 3.3-3.7 | ||
| 68 (20) | 2.4-2.8 | ||
| 104 (40) | 1.6-2.0 | ||
| 176 (80) | 0.5-0.9 | ||
|
|||